Filter Results By:

Products

Applications

Manufacturers

Showing results: 16 - 30 of 258 items found.

  • Multifunction Electrical Installation Meter

    AMPI-520 - Amperis sl

    The AMPI-520 digital meter is designed to measure impedance in short-circuit loops without tripping the differential protection, it also measures the protection tare, earth resistance, continuity and phase sequence check.

  • Multifunction Meter for Electrical Installations

    AMPI-525 - Amperis sl

    *Short circuit loop measurement:*Impedance measurement with 23 A (44 A phase-to-phase), short circuit resistance RZW =10Ω*Measuring range: 95...440V, frequency 45...65 Hz*Short circuit loop measurement with resolution 0,01 Ω , without tripping the differential protections (I∆n ≥30mA)*Automatic short-circuit calculation, phase-neutral and phase-phase voltage detection

  • Multifunction Electrical Installations Meter

    MPI-525 - Sonel S.A.

    Possible measurementsShort-circuit loop measurement:*impedance measurement with 23 A current (44 A phase-to-phase) - short-circuit resistor R=10,*measurement range: 95...440 V, frequency 45...65 Hz,Short-circuit loop measurement with resolution 0,01, in distribution network without tiggering RCD (In30 mA):*automatic calculation of short-circuit, detection of phase voltage and phase-to-phase voltage,*additional UNI-Schuko plug for automatic measurement, AGT adapter for 3 phase network measurement.Testing of general and selective RCD with the rated differential current of 10,30,100,300,500 and 1000 mA. (Type AC, A and B).Measurement of insulation resistance:*with test voltage 250 V, 500 V, 1000 V, 2500 V,*measurement range up to 10G,*automatic discharging after measurement,*automatic measurement of all resistences in 3,4,5-wire cables using optional adapter AUTO-ISO,*acoustic signals in 5 sec intervals for insulation resistance characteristic,*elapsing T1, T2, T3 times (0...600 s) form measurement of absorption coefficients (DAR, PI or Ab1, Ab2)*safety measurement - protection against overvoltage.Measurement of earthing resistance.Bi-directional testing of PE wire continuity using 200 mA current.*Autocalibration of test leads.

  • Multifunction Electrical Installations Meter

    MPI-502 - Sonel S.A.

    Short circuit loop parameters measurements:measurements of short circuit loop impedance in networks with rated voltage: 220/380 V, *230 V/400 V, 240/415 V and frequency 45...65 Hz,*measurements of short circuit loop impedance with current 15 mA without tripping the circuit breaker.Testing the RCD breakers of AC, A types:*testing of prompt, short-delay (general) and selective RCDs for the rated current values 10, 30, 100, 300, 500 mA,*IA measurement*RE and UB measurement without tripping the circuit breaker,*extended RCD test function AUTO, with measurement of ZL-PE with current 15 mA - measurement of IA and tA during one RCD tripping.Detection of the replacement L and N in the socket and automatic conversion in the meter.Low voltage resistance measurements of protective circuits and junctions:*measurement of resistance with ±200 mA current*calibration of test leads - possibility of using any length of test leads,*low current resistance measurement with accoustic signalling

  • Multifunction Meter for Electrical Installations

    AMPI-530 - Amperis sl

    Measurement of short-circuit loop ; Testing of differential, general and selective protections for differential current ; Measurement of insulation resistance ; Up to 10GΩ ; Voltages: 50 V, 100 V, 250 V, 500 V, 1000 V ; Measurement of earth resistance ; Bi-directional continuity test on PE cables, phase sequence ; Measurement and recording of voltage, frequency, alternating current, cosϕ, power, harmonics and THD

  • Multifunction Power Meter (DIN rail)

    CPM-12D - Chuan Sheng Electronics Co., Ltd.

    CPM-12D is a din rail mounting multifunction power meter with high accuracy measurement for single phase and three-phase system.Measuring all basic parameters ; V, I, P, Q, kWh, kVarh etc..

  • Three Phase Multifunction Static kWh Meter

    SY 1065 - Hong Kong Songyang Industrial Ltd.

    This kind of meter integrates many functions into one, realizes the functions of time-sharing electricity measurement for active double-direction, measuring demand, sinusoidal reactive, calculating power factor, displaying and tele-transmitting present voltage, current, power and load curve etc. and it realizes the function of recording all the missing voltage, missing current and the percent of pass for voltage,

  • PORTABLE THREE PHASE MULTIFUNCTION ELECTRIC METER CALIBRATOR

    GF312V2 - Beijing GFUVE Electronics Co.,Ltd.

    GF312V2 portable three phase multifunction energy meter calibrator is with comfort design, small size, and light weight. It is suit for electric power departments, measuring and quality examining departments and electric lab to field use.

  • Microprocessor Multifunction TRMS Power Meter + Harmonics Analyzer

    8100 C - Kusam Electrical Industries Limited

    INPUT :• Input Voltage Range :Voltage: 55 ~ 300V AC, or 300 ~ 600V AC, 45 ~ 65Hz.P.T. Ratio Programmable upto 9999 / KV.• Input Voltage Over Range :Voltage : 200 % Continuous, 300 % of rating for 10 sec.• Input Current Range :Current : 110 % of rating. 0-1A or 0 - 5AC.T. Ratio programmable upto 9999 / 5A.Input Current Over Range:Current : 400 % Continuous, 2000 % of rating for 10 Sec.• Input Frequency : 45 Hz ~ 70 Hz.• Input Burden :Voltage 0.25 VA / Unit, Current 0.25VA / Unit, at 50 / 60HzOUTPUTDC Current: 0 20 m A DCLoad resistance drive: output drive 10 V DC maximum.DC Voltage: 0 -10 V DCLoad resistance drive: output drive 5mA maximumOutput Protection: No damage even if output is Open or Short Circuit.Output Response Time : £ 1 Sec.Digital Output : RS485 Output, Isolate Type with MODBUS RTU mode., 4800, 9600,19200Baud Rate, User Selectable.

  • IR To USB PC Connectivity Cable For Handheld LCR/Capacitance/Multifunction Calibrator Meter

    U5481B - Keysight Technologies

    Connect easily to your PC from a handheld LCR meter or capacitance for faster data logging

  • PXI-6233, 16 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sinking DO, Bank-Isolated, PXI Multifunction I/O Module

    779620-01 - NI

    16 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sinking DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6233 is a bank-isolated DAQ device designed for voltage I/O. It offers analog I/O, digital input, sinking digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 24 V signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control. The PXI‑6233 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI‑6233 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.

  • PXI-6238, 8 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sourcing DO, Bank-Isolated, PXI Hybrid, Multifunction I/O

    779624-01 - NI

    8 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sourcing DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6238 is a bank-isolated DAQ device designed for current I/O. It offers analog I/O, digital input, sourcing digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 24 V signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control. The PXI‑6238 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI‑6238 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.

  • PXI-6230, 8 AI (16-Bit, 250 kS/s), 4 AO, 6 DI, 4 DO, Bank-Isolated, PXI Hybrid, Multifunction I/O

    779616-01 - NI

    8 AI (16-Bit, 250 kS/s), 4 AO, 6 DI, 4 DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6230 is a bank-isolated DAQ device designed for voltage I/O. It offers analog I/O, digital input, digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 5 V TTL/CMOS signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control. The PXI‑6230 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI‑6230 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.

  • PXI-6232, 16 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sourcing DO, Bank-Isolated, PXI Multifunction I/O Module

    779618-01 - NI

    16 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sourcing DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6232 is a bank-isolated DAQ device designed for voltage I/O. It offers analog I/O, digital input, sourcing digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 24 V signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control. The PXI‑6232 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI‑6232 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.

  • PXI-6239, 8 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sinking DO, Bank-Isolated, PXI Multifunction I/O Module

    779626-01 - NI

    8 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sinking DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6239 is a bank-isolated DAQ device designed for current I/O. It offers analog I/O, digital input, sinking digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 24 V signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control. The PXI‑6239 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI‑6239 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.

Get Help